Page 1 of 4

Text on page 2
Pe/Ppbags
Foottype-For
Impulse Sealer
Tisf-302.452.602.305.455.605
Operating Instruction
Thank You Very Much For Your Purchase Of
Tewimpulsesealer.This Product Was Designed
For Convenience And Performance,Pleaseread
THE FOLLOWING INFORMATION BEFOR USE.
Tewelectricheatingequipmentco.Lto
Tisf
Page 2 of 4

Text on page 3
Specifications:
Operating Instruction
1PLUG THE CABLE INTO AN Model TISF-300 TISF-450 TISF-600
Electrical Supply Socket
Impulse Power 400W 600W 800W Max.Seal Length 300mm 450mm 600mm Max.Seal Thickness 0.5mm 0.5mm 0.2~1.3(sec) 0.2~1.3(sec) HeatTime 0.2~1.3(sec.)
2SETSOURCEMAINSWITCHTO
23kg 28kg 34kg
On Position
3ADJUST THE TIMER(1-8) FOR
Minimum Setting Appropriate
To Thickness Of Seal Material
Additional Information
Always Keep The Sealing Platform Clean.Particular
4THESEALINGTIMEISINDICATED CARE BHOULD BE TAKEN TO REMOVE ANY RESIDUE FROM BY THE SIGNAL LIGHT ON THE OVERHEATED PLASTIC FROM THE BARRIER TAPE.
Time Panel And This Auto Ma-
Tic Ally Controls The He A-
If The Bottom Barrier Tape,(Undertheheating Element)
Ting Period When Pressing
BECOMESWORN,THEHEATINGELEMENTMAYSHORTTOEARTH,
THE FOOT PEDAL.
AND THIS CAN DAMAGETHE ELEMENT.
When Replacing Aheating Element Alwayscheck The
Condition Of The Bottom Barrier Tape
5LEAVE THE PRESSURE PEDAL IT IS ALSO IMPORTANT THAT,WHEN REPLACING A HEATING
Depressed Element,If Genuine Spares Are Not Available,Only Momentarily
Thermo-Electric Wire Of An Identical Specification
After The Pilot Light Has
Gone Out,No Powerwill (Resistivity)
Beused Other Than Ouring
AFTERA LONG PERIOD OF USETHE CONDITION OF THE TOP
THE SEALING. PRESSURE PAD SHOULD BE EXAMINED FOR WEAR.OBVIOUSLY
ANY DEFORMATION WILL AFFECT THE QUALITY OF THE WELD AND REPLACEMENT MAY BECOME NECESSARY.
Page 3 of 4

Text on page 4
Method Of Replace Subsidiary Parts
Instruction Booklet
Toreplace The Seal Parts Disused In Case Ofheater
Consumed,Please Refer Tofollowings:
- SINGNALLAMP 1,BESURETOTURNOFFTHEPOWERBEFOREREPLACING
- TRAMSFORMER TEFLON TAPE ①RELEASEFIXED TEFLON PRESSING
Mains Switch Teflonscrew
PLATETEFLON CLIP. 一KNOBFOR ②PULL OUT THE TEFLON TAPE,CUT
Pressing Lip
Timer Setting Down The Remainder,Then,Fix
PRESSING PLATE AND TAPE.
Pressing Platefor
Refractory Cloth Fix Teflonscrew,Then,Itmust
To Be Rotated,Pulltightly The
Heaing
Teflon Tape And Fix Teflonclip. Pressing Plate Element
- METHOD OF REPLACE HEATING ELEMENT
Sealing Press
Plate ①Releaseteflonclip
②HEARTER'SPOLEMUSTBEENCLOSED
To Inner Sideinorde To Release
Operating The Heating Element(Heater'S
Board Pole Is Tighened By At Two End.)
③AFTER REPLACETHE HEATER,PLEASE
Wireclip Fixthe Teflon Tape According To Teflon Clip
THE PREVIOUS METHOD.
Connection Diagram
Power Suppl
Tension Rod
Cord Mains
Switch
Source
Signallamp Relay
Standing Fuse
Tube
Pedal
Level Adjusting
For Board
Contruls
Specifications
Pedal Base
Tramsfomer
Limite
Heating Element Fuse10A Switch Heating
Element
Page 4 of 4 · End of manual
Quick start
- Plug in: Plug the cable into an electrical supply socket.
- Switch on: Set the source main switch to the On position.
- Set the timer: Adjust the timer (1 to 8) to the minimum setting that suits the thickness of the seal material.
- Seal: Press the foot pedal. The signal light on the time panel shows the sealing time and controls the heating period automatically.
- Release correctly: Keep the pedal pressed only until the pilot light has gone out.
- Keep it clean: Always keep the sealing platform clean.
Troubleshooting
| Problem | Likely cause | Fix (from the manual) |
|---|---|---|
| Residue builds up on the sealing platform | Overheated plastic stays on the barrier tape. | Keep the sealing platform clean and take care to remove any residue from the barrier tape. Page 3 |
| Heating element may be damaged | The bottom barrier tape under the heating element is worn, so the element may short to earth. | Check the condition of the bottom barrier tape whenever you replace a heating element. Page 3 |
| Seal quality is poor | The top pressure pad is worn or deformed. | Examine the top pressure pad after a long period of use. Replace it if it is deformed. Page 3 |
| Heating element needs replacing | The heater has been consumed. | Turn off the power first. Use genuine spares. If none are available, use thermo-electric wire of identical specification. Page 3 |
| Teflon tape needs replacing | The teflon tape has worn out. | Turn off the power. Release the teflon screw and clip, pull out the tape, fit new tape, then fix the screw and clip again. Page 4 |
Frequently asked questions
How do I set the sealing time?
Adjust the timer (1 to 8) to the minimum setting that suits the thickness of the seal material. See page 3.
Which models does this manual cover?
The specifications list the TISF-300, TISF-450, and TISF-600. The heading also lists 302, 452, 602, 305, 455, and 605. See page 3.
How long should I hold the foot pedal?
Leave the pedal pressed only until the pilot light has gone out. No power is used other than during sealing. See page 3.
What is the maximum seal length?
The TISF-300 seals up to 300 mm, the TISF-450 up to 450 mm, and the TISF-600 up to 600 mm. See page 3.
How do I replace the heating element?
Turn off the power, release the teflon clip, replace the heater, and fix the teflon tape back as before. See page 4.