TROUBLESHOOTING
MALFUNCTIONS
REASONS
SUGGESTIONS
No sealing Power lamp is off
Disconnected plug Power cord is broken Transformer is broken
Check or change the plug Replace or repair the cord Replace the transformer
No sealing Power lamp is on Sealing lamp is on
Heater (heating element) is broken Spring hook our mounting spring is loose or in poor contact Terminals of the heating element are in poor contact
Replace the heater Clean or tighten spring hook connection Clean the terminals and adjust if needed
No sealing Power lamp is on Sealing lamp is off
Microswitch is activated Defective microswitch
Adjust the microswitch lever Adjust the microswitch position Replace the microswitch
Timer malfunction Prolonged heating time
Replace timer or relay Decrease the timer setting
Replace the Teflon adhesive
Heating timer is set too high Cooling time is not enough
Lower the timer setting Continue pressing the upper lever for 1-2 seconds after the light goes off
Worn Teflon cloth Worn silicone rubber
Replace Teflon cloth Replace silicone rubber
Sealing time is too short
Dirty Teflon cloth Dirty sealing bar
Clean the Teflon cover Clean the silicone rubber sealing bar
LONG HAND IMPULSE SEALER
OPERATING INSTRUCTIONS MODELS FS-600H, FS-800H, FS-100H
Page 2 of 5

Text on page 3
IMPORTANT POINTS TO REMEMBER
SPECIFICATIONS
Model Power Sealing Length Seal Type Heating Time Weight (lbs)
FS-600H 110V/780W 23.6" 2.8mm 0.2-3 secs
FS-800H 110V/1050W 31.5" 2.8mm 0.2-3 secs
FS-1000H 110V/1350W 39.4" 2.8mm 0.2-3 secs
OPERATING INSTRUCTIONS
Before operating, check the heating element, PTFE cover, PTFE adhesive and sealing pad (silicone rubber). 1. Set the Power Switch to the ON position.
Adjust the timer setting according to the thickness of the sealing material. Note: Always start with the lowest setting and gradually increase to the correct setting.
Pull the film to be sealed in between the base and sealing jaw.
Place the object to be sealed between the sheets of film.
Press the sealing bar down and seal.
Wait 2-3 seconds to allow the seal to set and lift the handle.
ADDITIONAL INFORMATION
Always unplug the unit from the power source before attempting any maintenance.
Always keep the sealing platform clean and remove any residue found on the platform and Teflon tape. Silicone spray may be used for this purpose.
Read all instructions before use. Save these instructions for later use.
Follow all warnings and instructions marked on the product.
Unplug this product from the power source before cleaning and/or changing any parts
Do not rest anything on the power cord. Do not place the machine where the power cord may be stepped on or pulled.
Always keep out of reach of children and pets.
This sealer should only be in use with an operator in attendance.
Never insert clothing, hands, fingers between the sealing jaws of sealers.
Never touch the heating elements with bare hands while the sealer is plugged into a power source, or in operation, or just finished operation. It will be HOT.
Be sure to check for worn parts before starting operation.
Do not operate with a damaged power cord or plug.
Always keep the unit clean. Do not use water. Silicone spray may be used to clean the unit. Be sure the unit is unplugged from the power source before cleaning.
When changing blade (for sealers with cutters), be careful of the sharp edge.
When changing the teflon adhesive, be sure the entire surface under the heating element is covered with a teflon adhesive. Bend down the excess teflon adhesive on both ends. This prevents the heating element from breaking and the machine from grounding.
When replacing the fuse, be sure the exact voltage and ampere is used.
When replacing the Heating Element, always replace the PTFE adhesive.
Be sure to keep a record of your model number. Specify this number when ordering parts.
Occasionally check the condition of the Silicone Rubber for wear and burn. A damaged or worn Silicone Rubber will affect the quality of the seal.
When replacing any parts, be sure to mark down the exact locations of the connections.
Page 3 of 5

Page 4 of 5

Text on page 5
FS LONG HAND SEALER (FS-600H, FS-800H, FS-1000H) Parts DIAGRAM
Microsw itch w ith Arm
Microsw itch Fix ed Plate Holder
Control Knob/Timer Knob (same as FS-Hand)
Microsw itch Lev el Spring/see #38 Arm Spring
Skull Back Cov er
End Cap for Base
Fix ed Seat of Handle, Sealing Bar
Handle Knob w ith Screw
g Pin "C" Clip p for Hinge
Pow er Cord Restraint, Grommet
Screw for PC Board
Screw for Teflon Cov er Plate
Teflon Cloth Fix ed Plate
Screw for Skull Back Cov er
Microsw itch Holder and Screw
Transformer Fix ing Bar and Screw
Heating Element Cov er
Element Holder Front, Screw On
Rubber Foot w ith Screw
Element Holder Behind, Hook On
Mounting Piv ot, Screw for Silicone Rubber Holder
p g Silicone Rubber Holder Spring
Page 5 of 5 · End of manual
Quick start
- Check the heating element, PTFE cover, PTFE adhesive and silicone rubber sealing pad before use.
- Set the power switch to ON.
- Set the timer for the thickness of the material, starting at the lowest setting and increasing gradually.
- Pull the film between the base and the sealing jaw and place the item between the sheets of film.
- Press the sealing bar down to seal.
- Wait 2 to 3 seconds for the seal to set, then lift the handle.
Troubleshooting
| Problem | Likely cause | Fix (from the manual) |
|---|---|---|
| No sealing and power lamp is off | Disconnected plug, broken power cord or broken transformer | Check or change the plug, repair or replace the cord, or replace the transformer. Page 2 |
| No sealing with power and sealing lamps on | Broken heating element, loose spring hook, or poor contact at the element terminals | Replace the heater, clean or tighten the spring hook connection, or clean and adjust the terminals. Page 2 |
| No sealing with power lamp on and sealing lamp off | Microswitch activated or defective | Adjust the microswitch lever or position, or replace the microswitch. Page 2 |
| Seal is burned or overheated | Heating timer set too high or not enough cooling time | Lower the timer setting and keep pressing the lever for 1 to 2 seconds after the light goes off. Page 2 |
| Poor seal quality | Worn or dirty Teflon cloth, worn silicone rubber, or sealing time too short | Clean or replace the Teflon cloth and silicone rubber, and check the timer setting. Page 2 |
Frequently asked questions
How long a seal does the FS-1000H make?
39.4" long with a 2.8mm seal width. The FS-600H seals 23.6" and the FS-800H seals 31.5". See page 3.
What timer setting should I use?
Set it by material thickness. Always start at the lowest setting and increase gradually. Heating time ranges from 0.2 to 3 seconds. See page 3.
How do I clean the sealer?
Unplug it first, keep the sealing platform and Teflon tape free of residue, and use silicone spray rather than water. See page 3.
What power does it use?
110V at 1350W for the FS-1000H. See page 3.