Text on page 1
TROUBLESHOOTING
MALFUNCTIONS
REASONS
SUGGESTIONS
No sealing Power lamp is off
Disconnected plug Power cord is broken Transformer is broken
Check or change the plug Replace or repair the cord Replace the transformer
No sealing Power lamp is on Sealing lamp is on
Heater (heating element) is broken Spring hook our mounting spring is loose or in poor contact Terminals of the heating element are in poor contact
Replace the heater Clean or tighten spring hook connection Clean the terminals and adjust if needed
No sealing Power lamp is on Sealing lamp is off
Microswitch is activated Defective microswitch
Adjust the microswitch lever Adjust the microswitch position Replace the microswitch
Timer malfunction Prolonged heating time
Replace timer or relay Decrease the timer setting
Replace the Teflon adhesive
Heating timer is set too high Cooling time is not enough
Lower the timer setting Continue pressing the upper lever for 1-2 seconds after the light goes off
Worn Teflon cloth Worn silicone rubber
Replace Teflon cloth Replace silicone rubber
Sealing time is too short
Dirty Teflon cloth Dirty sealing bar
Clean the Teflon cover Clean the silicone rubber sealing bar
LONG HAND IMPULSE SEALER
OPERATING INSTRUCTIONS MODEL
WN-500H/HC, WN-650H/HC, WN-750H/HC, WN-1000H/HC, WN-1500HC