Text on page 11
Only qualified personnel should attempt to work on this equipment.
Most of the problems you may encounter are due to setup errors. There is one fuse located at the rear of the PC 2000 inserter that can be replaced by the customer. Below is a troubleshooting guide to help you through most of the problems that may be encountered.
Symptom Drive wheel does not rotate. (There is a thermal overload built inside of the motor. Wait several minutes before checking the fuse)
Possible Cause
- Machine is off. (Switch is in center position)
- Machine not plugged in.
- Blown Fuse.
- Handle not depressed.
Coil tightens on the mandrel when inserting.
- Mandrel is too large for coil.
Coil stops before it is completely through the book.
- The holes in the book are misaligned.
- The coil is beyond drive wheel.
Action
1) Place switch in either Forward or Reverse position.
2) Check both ends of power cord.
3) Check Fuse 1.
1) Select proper size mandrel. (See page 3)
1) This is normal. Try moving the book around so the coil rotates in the holes.
2) Coil length may need to be longer for that particular book. Note: Larger coils can wind themselves open so the length is actually less.
PC 2000 Electrical Schematic NOTE: The motor is protected by a
thermal overload located in the motor. It will reset automatically after the motor cools. 115VAC uses a 5 amp AGC fuse and a 5mf Capacitor. The 230VAC Model uses a 1 amp GDC Slow fuse and a 4mf Capacitor.