Page 1 of 21

Page 2 of 21

Text on page 3
THE O D 4000 PUNCH WITH OD 4300 PLASTIC
COIL INSERTER MODULE AND THE OD 4200 WIRE CLOSER MODULE
THE OD 4000 PUNCH WITH O D 4300 PLASTIC
COIL INSERTER MODULE AND THE OD 4400 COMB OPENER MODULE
THE HD 7500 24 INCH HEAVY DUTY PUNCH
THE HD 7000 14 INCH HEAVY DUTY PUNCH
THE HD 6500 14 INCH HEAVY DUTY PUNCH
THE OD 4000 1 1-1/2 INCH PUNCH
Page 3 of 21

Text on page 4
Optional OD 3500 Combo Binding Station, Modules & Accessories
Combo Binding Station & Modules
1) Attaching Coil Inserter module Setup Instructions
a) Determine the correct coil size
b) Determine the correct size mandrel
c) Installing the mandrel on the machine
d) Adjusting the Mandrel bracket
e) Adjusting the paper stop
f) Adjusting the front table / lexan guide
g) Forward / off / reverse switch
h) Inserting a coil i) Drive wheel stop screw j) Cutting a coil
2) Attaching Wire Closer module Setup Instructions
a) Determine the correct wire size
b) Inserting the wire into the book
c) Setting the closing bar height
d) Closing the book
3) Attaching Comb Opener module Setup Instructions
a) Determine the correct comb size
b) Placing the comb onto the rake
c) Setting the comb opener stop
d) Placing the book onto the comb
e) Margin settings
Setup Illustrations Coil Inserter Diagram 1 Diagram 2a Coil Inserter Diagram 2b Coil Inserter Diagram 2c Coil Inserter Diagram 2d Coil Inserter Diagram 2e Coil Inserter Diagram 2f Coil Inserter
Page 4 of 21

Text on page 5
Diagram 3 Wire Closer Diagram 4a Wire Closer Diagram 4b Wire Closer Diagram 4c Wire Closer Diagram 4d Wire Closer Diagram 5 Comb Opener Diagram 6 Comb Opener Troubleshooting Coil Inserter Module Electrical schematic Coil Inserter Module
Page 5 of 21

Text on page 6
Combo Binding Station
The Combo Binding Station is a base unit that supports three different binding modules. Each module attaches in a matter of minutes. The attachment procedure will be located in the module instructional section of this manual.
Coil Inserter
The Plastic Coil Inserter will bind books up to 1-1/8" (26.6mm) thick using coil diameter up to 1-1/4" (30mm) The unit attaches to the right side of the Combo Binding Station or the OD 4000 Punch using two wing nuts for easy installation.
Page 6 of 21

Text on page 7
Wire closer
The wire closer is capable of binding books up to 1-1/8" (28.6mm) thick. It uses wire sizes from 3/16 to 1 -1/4". It has an adjustable closing bar for the different size wires. Each end can be adjusted independently to obtain a perfect close. The unit attaches to the rear of the Combo Binding Station or the OD 4000 Punch using four knobs.
Comb opener The comb opener will bind books up to 2” (51 mm) thick. The opener has an adjustable ring opener control for exact book placement. The unit attaches to the rear of the Combo Binding Station or the OD 4000 Punch using four knobs.
All of the above modules can be ordered when ordering the Combo Binding Station or individual units can be ordered at a latter date. Each unit can be installed in a matter of minutes. The coil inserter can be attached and kept on the Combo Binding Station or the OD 4000 Punch permanently. If the Wire closer module is installed on the Combo Binding Station or the OD 4000 Punch and the Comb opener module is required: the wire closer will have to be removed so that the comb opener can be installed. The opposite is also true. It only takes a few minutes to detach any one of the modules to install any other one.
Page 7 of 21

Text on page 8
Coil Inserter Module
- Installation Instructions: Diagram 1 Procedure to attach the coil inserter onto the Combo Binding Station or the OD 4000 Punch.
+ Align the t w o threaded studs (1) that protrude from the coil inserter option into the two holes located on the right side of the Combo Binding Station or OD 4000 Punch. + Use the two wing nuts provided with the coil inserter to attach the unit. Hand tighten the two wing nuts. + Anach the paper stop bracket (2) to the right side of the Combo Binding Station or OD 4000 Punch using the two black thumb knobs (3) provided. + Use two black thumb knobs (4) to attach the book table / lexan coil guide to the Combo Binding Station or OD 4000 Punch. (The book table / lexan guide has been removed to view the diagram, see diagram 10b to view the book table / lexan guide in position) + Plug one end of the power cord into the back of the coil inserter option and the other end into the wall outlet.
Page 8 of 21

Text on page 9
Setup Instructions: Diagram 2a, 2b, 2c, 2d & 2e Determine the correct coil size. a)
Use a coil that is at least 3/32 (2.5mm) larger than the book thickness for coil sizes up to 3/4" (2Omm). After 3/4”, use a coil size of at least 1/8" over the book size. The larger the coil compared to the book, inserting will become much easier.
Determine the correct size mandrel.
There are a total of nine mandrels, which are used for coil sizes 3/16” (5mm) up to 1-1/4" (3Omm). Use the below table to choose the correct mandrel size to coil size.
3/1 6" to 1/4” 5/1 6" 3/8" 7/16" to 1/2" 9/1 6" 3/4" 7/8" 1" 1-1/8" to l-l/P
(5mm-6mm) (7mm-8mm) (9mm-1Omm) (1 mm-12mm) (13mm-16mm) (17mm-19mm) (20mm-23mm) (24mm-27mm) (28mm-30mm)
Installing the mandrel on the machine
Place the mandrel (1) into the mandrel holder bracket (2) making sure the beveled edge of the mandrel is facing the right side of the machine. Both guide pins located on the mandrel need to line up with both slots on the mandrel bracket. Use the black knob (3) to tighten the mandrel in place. + Adjust the height of the mandrel so the center of the mandrel is the same height as the center of the book.
Adjusting the mandrel bracket,
+ The mandrel assembly-adjustment knob (4) is located on the right side of the coil inserter, Move the mandrel bracket assembly towards the drive wheel for small mandrels and away from the drive wheel for the larger mandrels. + The mandrel holder bracket-adjustment knob (5) can be adjusted to the left or the right so the leading edge of the coil lines up with the first hole of the book.
Page 9 of 21

Text on page 10
Adjusting the paper stop.
Place the book on top of the Combo Binding Station or the OD 4000 Punch with the right side of the book against the paper stop bracket. Adjust the paper stop (6) so the holes of the book hang over the edge of the Combo Binding Station or OD 4000 Punch. The holes should hang over the edge just enough for the coil to clear the edge of the Combo Binding Station or the OD 4000 Punch. Tighten the knob located on the paper stop bracket. It may be necessary to fine-tune this after a few books are bound for exact placement.
Adjusting the front table / lexan guide
The front table/ lexan guide (7,7a & 7b) has two purposes. (FIRST): When the lexan is in the closed position, rotated on top of the coil (7a), it will assist the coil to insert smoothly into the book. You should use the lexan guide with all books regardless of thickness. (SECOND): With the lexan guide (plastic) in the open position, rotated away from the machine, it acts as a support table (7b) for large books. For book’s over 9/16" thick, it may be necessary at times to start the coil into the book, then split the book in half using the table to support one half of the book, then finish the inserting of the coil. This method improves productivity.
Page 10 of 21

Text on page 11
Forward /off / reverse switch.
The forward / off / reverse (8) switch has three positions. The center position of this switch is the off position and should be placed in this position when not using the machine. Press the left side (forward) of the switch and the coil will rotate into the book. Press the right side (reverse) of the switch and the coil will exit the book. The reverse feature allows the coil to be removed from the book. Sometimes this will be necessary when the leading edge of the coil misses a hole of a single sheet.
Place the coil on the mandrel by sliding the open end of the coil onto the
beveled end of the mandrel. Turn the coil so it threads onto the mandrel post (9) and is in front of the drive wheel by one coil. Make sure the forward / reverse switch is in the forward position. Pull the motor handle
- down to start the motor and engage the drive wheel (11) to the coil.
Rotate the coil so it comes close to the edge of the book, but not past the book. With your right hand, hold the leading edge of the coil and thread it through the first two holes of the book. This helps align the holes of the book. Rotate the lexan guide on top of the coil. Pull the handle down gently at first making sure the coil is rotating into the book without missing
Page 11 of 21

Text on page 12
holes in the sheets or covers. Continue until the coil is past the left side of the book by about one or two coils.
Drive wheel stop screw.
The drive wheel stop screw (12) will prevent the wheel from pressing to hard on the mandrel. It is very important not to have too much pressure on the mandrel when inserting the larger coils. If the leading edge of the coil stops on a misaligned sheet, the coil wants to tie itself into a knot between the book and the end of the mandrel. Setting the stop screw will prevent this from happening most of the time. To set the stop screw, turn it clockwise to push the wheel away from the mandrel. Load the coil onto the mandrel and turn the stop screw counter clockwise while holding down on the motor handle (10) until the drive wheel touches the coil. Try a few books and readjust if necessary. If the mandrel bracket is adjusted after the stop screw has been adjusted, it will be necessary to readjust the stop screw.
There are special cutter crimper pliers (ordered separately) that are used to terminate the ends of the coil. After the coil is cut, the sharp end of the coil will tuck itself under the inside of the coil opening. To use the cutter, make sure the red dot (13) is facing up. Place the cutter on the
Page 12 of 21

Text on page 13
edge of the right hand side of the book. Open the cutter enough so that the end of the cutter enters the coil by about a 1/4" Make sure the cutter is level with the book before you cut. As you squeeze the cutters you may notice the coil wants to twist. You can support the coil with your fingers as you cut to help stabilize the coil. Turn the book over and repeat these steps on the opposite end of the book. Always make sure to close
Page 13 of 21

Text on page 14
Wire Closer Module
- Installation Instructions: Diagram 3
Procedure to attach the wire closer onto the Combo Binding Station or the OD 4000 Punch. Place the closer module on the backside of the Combo Binding Station or the OD 4000 Punch so the closer adjustment knobs are facing the front of the Combo Binding Station or the OD 4000 Punch and are pointing up. Attach the closer with four black knobs (1) provided with the closer module. Use two knobs on each side to secure the unit in position. Attach the closing handle (2) either to the right or left side of the closer using the screw (3) provided with the closing module. Use the allen key provided with the closing module to secure the handle in place. The book table / lexan guide & the top paper stop assembly should be removed while using the wire closing module. (Combo Binding Station or OD 4000 Punch fitted with Coil Inserter Module Only)
Page 14 of 21

Text on page 15
Coil Inserter Module Electrical Schematic
(120 volt AC)
Power Entry Module
NOTE: The motor is protected by a thermal overload located in the motor. It will reset automatically after the motor cools.
This product has earned the UL Listing Mark and the UL Listing Mark for Canada. El 79574
The Cl 3000 has been tested with a duty cycle of 4 seconds on, 15 seconds off
with a rest period of 2 minutes after 30 seconds of run time.
The Cl 3000 is also know as the Coil Inserter Module OD 4300.
Page 15 of 21

Text on page 16
Wire Closer Module
- Installation Instructions: Diagram 3 Procedure to attach the wire closer onto the Combo Binding Station or the OD 4000 Punch. Place the closer module on the backside of the Combo Binding Station or the OD 4000 Punch so the closer adjustment knobs are facing the front of the Combo Binding Station or the OD 4000 Punch and are pointing up. Attach the closer with four black knobs (1) provided with the closer module. Use two knobs on each side to secure the unit in position. Attach the closing handle (2) either to the right or left side of the closer using the screw (3) provided with the closing module. Use the allen key provided with the closing module to secure the handle in place. The book table / lexan guide & the top paper stop assembly should be removed while using the wire closing module. (Combo Binding Station or OD 4000 Punch fitted with Coil Inserter Module Only)
Page 16 of 21

Text on page 17
Setup Instructions: Diagram 4a, 4b, 4c & 4d
- Determine the correct wire size.
Use the table below to determine the correct wire size for the book thickness. You can insert more sheets into the wire, but it may affect the appearance of your book. Covers are not included with the number of sheets column.
Wire Diameter Inch 3/16 z 1/4 6.4 5/16 7.9 3/8 9.5 7/16 11.1 1/2 12.7 9/16 14.3 5/8 15.9 3/4 7/8 22.2 25.4 1-1/4 31.8
Book Thickness Inch 1/8 z 3/16 4.8 1/4 6.4 5/16 7.9 3/8 9.5 7/16 11.1 1/2 12.7 9/16 14.3 5/8 15.9 3/4 7/8 22.2 1-1/8 28.6
Number of sheets 20lb 80gsm
- inserting the wire into the book.
First, prep the book by removing the back cover and place it on top of the front cover. This will position the binding edge of the wire at the inside cover at the back of the book. Place the book on the edge of a table so the holes overhang the table a slight amount. Make sure the covers are facing down and under the main body of text when placing the book on the table. Insert the narrow loop into the holes of the book with a slight rotating action. Start with the left side and slide your finger along the wire to thread it into the remaining holes.
Page 17 of 21

Text on page 18
- Setting the closing bar height
The closing bar is adjustable on each end allowing the operator to achieve a perfect close at each end of the book. Pull the handle on the closer all the way down and adjust both knobs (3) so the top edge (4) of the closing bar lines up with the line (5) next to the wire size you want to close.
With the handle in the full upright position place the book so the open end of the wire is firmly pressed against the back plate (6) inside the closing machine (see diagram 4c on page 16). The narrow loop (7) should be on the top of the book while pushing the book against the back plate. Hold the book as you pull the handle (8) down. Inspect the close and readjust the closing bar if necessary. When the wire is closed properly, the narrow loop overlaps the wide loop by about 1/16" along the entire length of the book. An indication that the wire is not closed tight enough is when the covers or sheets fall out of the book.
Page 18 of 21

Page 19 of 21

Text on page 20
Comb Opener Module
- Installation Instructions: Diagram 5 Procedure for attaching the comb opener onto the Combo Binding Station or OD 4000 Punch. Place the comb opener module on the backside of the Combo Binding Station or OD 4000 Punch so the narrow section of the comb opener is facing the front. Attach the comb opener with four black knobs (1) provided with the comb opener module. Use two knobs on each side to secure the unit in position. Anach the comb opener handle (2) either to the left or right side of the comb opener using the screw (3) provided with the comb opener module. Use the allen key provided with the comb opener module to secure the handle in place.
Page 20 of 21

Text on page 21
- Determine the correct comb size.
Use the table below to determine the correct comb size for the book thickness. You can insert more sheets into the comb, but it may affect the appearance of your book. Covers are not included with the number of sheets column.
Comb Diameter Inch E 3/16 1/4 6.4 5/16 7.9 3/8 9.5 7/16 11.1 12.7 1/2 9/16 14.3 5/8 15.9 3/4 7/8 22.2 25.4 1-1/8 28.6 1-1/4 31.8 1-1/2 38.1 44.5 1-3/4 50.8
Book Thickness Inch 1/8 E 3/16 4.8 1/4 6.4 5/16 7.9 3/8 9.5 7/16 11.1 12.7 1/2 9/16 14.3 5/8 15.9 3/4 7/8 22.2 25.4 27.8 1-3/32 1-3/16 30.1 1-7/1 6 36.5 1-11/16 42.8
Number of sheets 20lb 80gsm
- Placing the comb onto the rake. Diagram 6
Place the comb onto the rake with the fingers of the comb facing the from of the machine. The solid section of the comb will be facing the rear of the machine. Make sure the points of the fingers are facing up. Pull the opener handle down to open the fingers of the comb.
- Setting the comb opener stop. Diagram 5
The comb opener stop knob (4) is located on the rear of the comb opener. Set the comb opener stop by turning the knob counter clockwise so the comb opens far enough to place a book on the fingers of the comb, but not to far so the comb is lying flat with no room for the book.
Page 21 of 21 ยท End of manual
Quick start
- Attach the coil inserter: align the two threaded studs with the two holes on the right side of the Combo Binding Station, hand-tighten the two wing nuts, fit the paper stop bracket and the book table / lexan guide with the black thumb knobs, and plug in the power cord.
- Choose the coil and mandrel: use a coil at least 3/32 (2.5mm) larger than the book for coils up to 3/4", and at least 1/8" over the book size above that. Pick the matching mandrel from the nine-mandrel table.
- Fit the mandrel: place it in the holder bracket with the beveled edge facing the right side, line up both guide pins with the slots, tighten the black knob, and set the mandrel center to the same height as the book center.
- Set the paper stop: adjust it so the holes of the book hang over the edge just enough for the coil to clear, then tighten the knob.
- Insert the coil: slide the coil onto the mandrel, thread the leading edge through the first two holes by hand, rotate the lexan guide over the coil, and pull the motor handle down gently until the coil is one or two coils past the left side of the book.
- Finish the coil: trim both ends with the cutter crimper pliers (ordered separately), keeping the red dot facing up and the cutter level with the book.
- Swap to wire or comb: remove the book table / lexan guide and paper stop, then attach the wire closer or comb opener to the rear with the four black knobs and fit its handle with the screw and allen key provided.
- Close wire books: set the closing bar to the line for your wire size, press the open end of the wire against the back plate with the narrow loop on top, and pull the handle down.
Troubleshooting
| Problem | Likely cause | Fix (from the manual) |
|---|---|---|
| Coil ties itself into a knot at the end of the mandrel | Too much drive wheel pressure, often with a misaligned sheet | Set the drive wheel stop screw so the wheel just touches the coil, and readjust it after any mandrel bracket change. Page 12 |
| Leading edge of the coil misses a hole | Coil did not thread through a single sheet | Press the right side (reverse) of the switch to back the coil out of the book, then insert it again. Page 11 |
| Coil does not rotate | Switch is in the center (off) position | Press the left side (forward) of the switch. Page 11 |
| Motor stops during heavy use | Thermal overload in the motor tripped | Let the motor cool. The overload resets automatically. Follow the duty cycle of 4 seconds on and 15 seconds off. Page 15 |
| Leading edge of the coil does not line up with the first hole | Mandrel holder bracket position | Turn the mandrel holder bracket adjustment knob to move the bracket left or right. Page 9 |
| Large books are slow to coil | Book is over 9/16" thick | Start the coil, split the book in half with one half on the open lexan support table, then finish inserting the coil. Page 10 |
| Covers or sheets fall out of a wire bound book | Wire is not closed tight enough | Readjust the closing bar knobs and close again until the narrow loop overlaps the wide loop by about 1/16" along the whole book. Page 18 |
| Comb opens flat with no room for the book | Comb opener stop is set too far | Reset the comb opener stop knob at the rear so the comb opens far enough to place the book, but not flat. Page 21 |
| Comb opener cannot be installed | The wire closer module is still attached | Remove the wire closer first. Only one of the wire closer or comb opener fits at a time. Page 7 |
Frequently asked questions
What modules can the OD3500 Combo Binding Station use?
It supports three modules: a plastic coil inserter, a wire closer and a comb opener. Each attaches in a matter of minutes, and the modules also fit the OD 4000 Punch. See page 6, page 7.
How thick a book can each module bind?
The coil inserter binds books up to 1-1/8" thick with coils up to 1-1/4". The wire closer binds books up to 1-1/8" thick with wire sizes from 3/16 to 1-1/4". The comb opener binds books up to 2" (51 mm) thick. See page 6, page 7.
Can I keep all the modules installed at once?
The coil inserter can stay on permanently. The wire closer and comb opener both mount on the rear, so you must remove one to install the other, which takes only a few minutes. See page 7.
What is the duty cycle of the coil inserter?
It was tested at 4 seconds on and 15 seconds off, with a rest period of 2 minutes after 30 seconds of run time. It runs on 120 volt AC, and the motor has a thermal overload that resets automatically after cooling. See page 15.